Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
BMC Med ; 22(1): 130, 2024 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-38519982

RESUMO

BACKGROUND: Comprehensive data on patients at high risk of sudden cardiac death (SCD) in emerging countries are lacking. The aim was to deepen our understanding of the SCD phenotype and identify risk factors for death among patients at high risk of SCD in emerging countries. METHODS: Patients who met the class I indication for implantable cardioverter-defibrillator (ICD) implantation according to guideline recommendations in 17 countries and regions underrepresented in previous trials were enrolled. Countries were stratified by the WHO regional classification. Patients were or were not implanted with an ICD at their discretion. The outcomes were all-cause mortality and SCD. RESULTS: We enrolled 4222 patients, and 3889 patients were included in the analysis. The mean follow-up period was 21.6 ± 10.2 months. There were 433 (11.1%) instances of all-cause mortality and 117 (3.0%) cases of SCD. All-cause mortality was highest in primary prevention (PP) patients from Southeast Asia and secondary prevention (SP) patients from the Middle East and Africa. The SCD rates among PP and SP patients were both highest in South Asia. Multivariate Cox regression modelling demonstrated that in addition to the independent predictors identified in previous studies, both geographic region and ICD use were associated with all-cause mortality in patients with high SCD risk. Primary prophylactic ICD implantation was associated with a 36% (HR = 0.64, 95% CI 0.531-0.802, p < 0.0001) lower all-cause mortality risk and an 80% (HR = 0.20, 95% CI = 0.116-0.343, p < 0.0001) lower SCD risk. CONCLUSIONS: There was significant heterogeneity among patients with high SCD risk in emerging countries. The influences of geographic regions on patient characteristics and outcomes were significant. Improvement in increasing ICD utilization and uptake of guideline-directed medical therapy in emerging countries is urgent. TRIAL REGISTRATION: ClinicalTrials.gov, NCT02099721.


Assuntos
Desfibriladores Implantáveis , Humanos , Fatores de Risco , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/prevenção & controle , África , Oriente Médio
2.
Heart Rhythm ; 17(3): 468-475, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31561030

RESUMO

BACKGROUND: Implantable cardioverter-defibrillators (ICDs) are underutilized in Asia, Latin America, Eastern Europe, the Middle East, and Africa. The Improve SCA Study is the largest prospective study to evaluate the benefit of ICD therapy in underrepresented geographies. This analysis reports the primary objective of the study. OBJECTIVES: The objectives of this study was to determine whether patients with primary prevention (PP) indications with specific risk factors (1.5PP: syncope, nonsustained ventricular tachycardia, premature ventricular contractions >10/h, and low ventricular ejection fraction <25%) are at a similar risk of life-threatening arrhythmias as patients with secondary prevention (SP) indications and to evaluate all-cause mortality rates in 1.5PP patients with and without devices. METHODS: A total of 3889 patients were included in the analysis to evaluate ventricular tachycardia or fibrillation therapy and mortality rates. Patients were stratified as SP (n = 1193) and patients with PP indications. The PP cohort was divided into 1.5PP patients (n = 1913) and those without any 1.5PP criteria (n = 783). The decision to undergo ICD implantation was left to the patient and/or physician. The Cox proportional hazards model was used to compute hazard ratios. RESULTS: Patients had predominantly nonischemic cardiomyopathy. The rate of ventricular tachycardia or fibrillation in 1.5PP patients was not equivalent (within 30%) to that in patients with SP indications (hazard ratio 0.47; 95% confidence interval 0.38-0.57) but was higher than that in PP patients without any 1.5PP criteria (hazard ratio 0.67; 95% confidence interval 0.46-0.97) (P = .03). There was a 49% relative risk reduction in all-cause mortality in ICD implanted 1.5PP patients. In addition, the number needed to treat to save 1 life over 3 years was 10.0 in the 1.5PP cohort vs 40.0 in PP patients without any 1.5PP criteria. CONCLUSION: These data corroborate the mortality benefit of ICD therapy and support extension to a selected PP population from underrepresented geographies.


Assuntos
Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis/estatística & dados numéricos , Prevenção Primária/métodos , Medição de Risco/métodos , Taquicardia Ventricular/terapia , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/etiologia , Feminino , Saúde Global , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Prospectivos , Fatores de Risco , Taxa de Sobrevida/tendências , Taquicardia Ventricular/complicações
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...